GS1 DataBar Omnidirectional
GS1 DataBar Omnidirectional
The following options apply to the GS1 DataBar Omnidirectional (formerly
GS1 DataBar Omnidirectional Enable/Disable
When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Omnidirectional = Disable
GS1 DataBar Omnidirectional = Enable
GS1 DataBar Omnidirectional GS1-128 Emulation
When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1- 128 label data format.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Omnidirectional
GS1 DataBar Omnidirectional
Product Reference Guide | 143 |