ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1.Determine the desired setting in milliseconds.
2.Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.
4.Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 10 for some examples of how to set this feature.
Table 10. ACK NAK Timeout Value Setting Examples
STEP | ACTION |
| EXAMPLES |
| ||
|
|
|
|
|
| |
1 | Desired Setting | 200ms | 1,000ms (1 sec.) | 5200ms (5.2 sec.) | 15,000ms (1 sec.) | |
|
|
|
|
|
| |
2 | Divide by 200 | 01 | 05 | 26 | 75 | |
|
|
|
|
|
| |
3 | Scan ENTER/EXIT PROGRAMMING MODE |
|
|
| ||
|
|
|
|
| ||
4 | Scan SELECT ACK NAK TIMEOUT VALUE SETTING |
|
|
| ||
|
|
|
|
|
| |
5 | Scan Two Characters From | ‘0’ and ‘1’ | ‘0’ and ‘5’ | ‘2’ and ‘6’ | ‘7’ and ‘5’ | |
Appendix E, Keypad | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
7 | Scan ENTER/EXIT PROGRAMMING MODE |
|
|
| ||
|
|
|
|
|
|
56 | QuickScan® QD2100 |