LED and Beeper Indications

INDICATION

DESCRIPTION

LED

BEEPER

 

 

 

 

 

 

 

 

 

The imager is in the process of pow-

 

Imager beeps four times at highest

Power-up Beep

 

frequency and volume upon power-

ering-up.

 

 

 

up.

 

 

 

 

 

 

 

 

 

LED behavior for this indica-

The imager will beep once at cur-

Good Read Beep

A label has been successfully

tion is configurable via the

rent frequency, volume, mono/bi-

scanned by the imager.

feature “Good Read: When to

tonal setting and duration upon a

 

 

 

Indicate

successful label scan.

 

 

 

 

ROM Failure

There is an error in the imager's

Flashes

Imager sounds one error beep at

software/programming

highest volume.

 

 

 

 

 

 

Limited Scanning

Indicates that a host connection is

 

Imager 'chirps' six times at the high-

not established when the IBM or

N/A

Label Read

est frequency and current volume.

USB interface is enabled.

 

 

 

 

 

 

 

 

Imager Active

The imager is active and ready to

The LED is lit steadilya

N/A

Mode

scan.

 

 

 

 

 

 

Imager

The imager has been disabled by

The LED blinks continuously

N/A

Disabled

the host.

 

 

 

 

 

 

 

While in Stand Mode or Trigger

 

 

Green Spot is on

Object Sense mode the green spot

N/A

N/A

continuously

shall be on while in stand watch

 

 

 

state.

 

 

 

 

 

 

Green Spota

Upon successful read of a label, the

 

 

software shall turn the green spot on

 

 

flashes momen-

N/A

N/A

for the time specified by the config-

tarily

 

 

ured value.

 

 

 

 

 

 

 

 

 

Programming Mode - The following indications ONLY occur when the imager is in Programming Mode.

 

 

 

 

Label Programming

A valid programming label has been

LED blinks continuously

Imager sounds four low frequency

Mode Entry

scanned.

beeps.

 

 

 

 

 

Label Programming

 

 

Imager sounds three times at low-

Mode Rejection of

A label has been rejected.

N/A

est frequency & current volume.

Label

 

 

 

 

 

 

 

 

 

 

In cases where multiple labels must

 

 

Label Programming

be scanned to program one feature,

 

Imager sounds one short beep at

Mode Acceptance

this indication acknowledges each

N/A

highest frequency & current volume.

of Partial Label

portion as it is successfully

 

 

 

 

scanned.

 

 

 

 

 

 

Label Programming

Configuration option(s) have been

 

Imager sounds one high frequency

successfully programmed via labels

 

Mode Acceptance

N/A

beep and 4 low frequency beeps

and the imager has exited Program-

of Programming

 

followed by reset beeps.

ming Mode.

 

 

 

 

 

 

 

 

Label Programming

 

 

Imager sounds two times at low fre-

Mode Cancel Item

Cancel label has been scanned.

N/A

quency and current volume.

Entry

 

 

 

 

 

a.Except when in sleep mode or when a Good Read LED Duration other than 00 is selected