RS-232/USB-Com Interfaces

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.

To set this feature:

1.Determine the desired setting.

2.Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

4.Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.

5.Scan the appropriate three digits from the keypad in Appendix E, Keypad, that repre- sent the number which was determined in the steps above. You will hear a two-beep indi- cation after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 11 for some examples of how to set this feature.

Table 11. ACK NAK Retry Count Setting Examples

STEP

ACTION

 

 

EXAMPLES

 

 

 

 

 

 

 

 

1

Desired Setting

Disable Retry

3 Retries

 

54 Retries

Unlimited Retries

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Pad with leading zero(es)

000

003

 

054

255

 

 

 

 

 

 

 

3

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

4

Scan SELECT ACK NAK RETRY COUNT SETTING

 

 

 

 

 

 

 

 

 

 

 

5

Scan Three Characters From

‘0’, ‘0’ and ‘0’

‘0’, ‘0’ and ‘3’

 

‘0’, ‘5’ and ‘4’

‘2’, ‘5’ and ‘5’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

 

58

QuickScan® QD2100

Page 66
Image 66
Datalogic Scanning QD2100 manual ACK NAK Retry Count Setting Examples