Datamax PE manual Appendix E, Error Codes

Models: PE

1 100
Download 100 pages 9.34 Kb
Page 87
Image 87

Appendix E

Error Codes

The most common error codes transmitted by the Printer are described below.

Lower case “c”

Printer received a data byte from the host that contains a

 

framing error (corrupted) due to noise.

Lower case "e"

Memory module won't clear. Retry after a <STX> W

 

command.

Lower case “v”

Input buffer overflow.

Upper case “I”

This means that an invalid command sequence was sent to

 

the Printer. The Printer did not understand the command

 

sequence and terminated the command interpreter.

Upper case “R”

This code will be sent every time the Printer is turned on,

 

this means there was a hardware reset.

Upper case “T”

This means that the Printer has had a watchdog time-out

 

condition. This is how a software reset occurs. A software

 

reset is made by sending the command sequence to the

 

Printer or by doing a front panel reset.

BELL HEX “07”

This is usually returned on a corrupt image download, or if

 

you try to load an image that is already installed in the

 

module.

PE Series Operator’s Manual

E-1

Page 87
Image 87
Datamax PE manual Appendix E, Error Codes