Welcome to CarChip

 

Trouble Log Summary View

 

 

Date and time, vehicle ID, trouble code, problem description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble Log Problem View

 

 

Date and time, vehicle ID, CarChip ID, trouble code, problem

 

 

 

 

 

description, comments, OBDII freeze frame info (parameters

 

 

 

 

 

included in freeze frame vary from car to car)

 

 

 

 

 

 

 

 

 

 

Data Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported Unit Systems

 

 

U.S., Metric, S.I., custom

 

 

 

 

 

 

 

 

 

 

 

 

Vehicle Speed Sampling Interval

 

 

1, 5, 10, 20, 30 or 60 seconds

 

 

 

 

 

 

 

 

 

 

 

Other Parameters Sampling Intervals

5, 10, 20, 30, or 60 seconds

 

 

 

 

(E/X only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vehicle Speed Bands

 

 

4, user configurable, use to identify typical vs atypical

 

 

 

 

 

vehicle operation

 

 

 

 

 

 

 

 

 

 

 

 

Calculated Data

 

 

Hard and extreme braking, hard and extreme acceleration

 

 

 

 

 

 

 

 

 

Data Parameters for CarChip and CarChip E/X

 

 

 

 

 

 

 

 

 

Parameter

Range*

Resolution*

 

 

 

 

 

 

 

 

 

 

Vehicle Speed

0 to 158 mph, 0 to 255 kph, 0 to 70

0.6 mph, 1 kph, 0.3

 

 

 

m/s

 

m/s

 

 

 

 

 

 

 

Trip Distance Traveled

0 to 10,000 miles, 0 to 16,000 km

0.1 m, 0.1 km

 

 

 

 

 

 

 

Acceleration/Deceleration

0 to 3 G, 0 to 30 m/sec2

0.03 G, 0.3 m/sec2

 

 

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

*Range and resolution of sensor measurements only. Accuracy is dependent on the accuracy of the

 

 

vehicle’s sensors.

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Parameters for CarChip E/X Only

 

 

 

 

 

 

 

 

 

Parameter

Range*

Resolution*

 

 

 

 

 

 

 

 

 

 

Engine Speed

0 to 16,384 rpm

1 rpm

 

 

 

 

 

 

 

 

Throttle Position

0 to 100%

0.1%

 

 

 

 

 

 

 

 

Coolant Temperature

-40° to +420°F, -40° to +215°C

2°F, 1°C

 

 

 

 

 

 

 

 

Engine Load

0 to 100%

0.1%

 

 

 

 

 

 

 

 

Air Flow Rate

0 to 8714 lb/min, 0 to 655.35

0.1 lb/min, 0.01

 

 

 

gm/sec

gm/sec

 

 

 

 

 

 

 

Intake Air Temperature

-40° to +420°F, -40° to +215°C

2°F, 1°C

 

 

 

 

 

 

 

Intake Manifold Pressure

0 to 75 in. hg., 0 to 255 kPaA

0.3 in. hg., 1 kPaA

 

 

 

 

 

 

 

 

 

87

Page 91
Image 91
Davis Instruments 8245, 8241, 8246, 8226, 8211, 8220, 8221, 8225, 8210 manual Parameter Range Resolution