5.7 TIMED BLAST FREEZING

 

 

 

 

• Press push-button 4 0ο (relative LED lights up), then press push-button 5

to select the timer mode

(LED 5B

on). Display 15

shows the maximum chilling time (set by default to 240 minutes).

To modify this time, press push-buttons 7

and 8

(time in minutes).

 

Start up the cycle by pressing push-button 6 . LED 5B and push-button LEDs remain on and LEDs 13 flash throughout the cycle.

Internal cell temperature is shown on display 16 οC .

When the maximum chilling time has counted back to 0, the cycle is completed and the appliance automatically switches to the set negative storage temperature for an indefinite interval.

LEDs illuminate and the beep is activated when the cycle is finished (as in the freezing cycle by temperature). The same applies for the storage function. The factory setting for negative storage temperature is -13°F / -25°C.

Press push-button 6 to set the appliance to STOP status (relative LED switches off), ready for a new cycle.

IMPORTANT: During chilling or shock freezing by time it’s possible to read the evaporator temperature by pressing push button

HACCP

Page 15
Image 15