2. Installation

2.1Data plate information

Check that the data specified on the plate correspond to the characteristics of the power supply (V, kW, Hz, no. phases and power available).

The dataplate with appliance specifications

is located at the rear exterior of the machine and/or on the electrical boards (fig. 3). The set- up of individual units and the installation of condensers are subject to the fire-safety regulations

of the country in which the machine is installed; seek all necessary advice from the local fire- fighting authorities. Bear in mind that the intervention of safety valves or plug fuses in the refrigerating circuit will lead to the immediate discharge of refrigerant into the environment.

2.2Positioning

The machine must be installed in complete compliance with safety regulations, procedures and standing laws.

Position the machine in the allocated site.

Adjust the machine feet by turning the foot clockwise until the appliance is perfectly level. In the case of particularly heavy equipment, use appropriate lifting means.

(fig. 4).

• If the appliance is not perfectly level, correct operation and condensate flow-off will not be assured.

AVOID

direct exposure to sunlight;

closed sites with high temperatures and poor air circulation;

installing the machine near sources of heat

Installation Clearance Requirements

All Cabinets:

12” clearance above top

12” clearance on sides and rear Remote condensing units for T20, T24 and T40 models.

24” clearance above top

6” clearance on sides and rear

2.3 Ambient temperature and air circulation For air-cooled appliances, the maximum ambient

temperature for operation is 90°F / 32°C. Correct operation cannot be guaranteed at higher temperatures. The machine may operate safely to a maximum temperature of 100°F / 38°C. Remote condensing units may be installed indoors next to the unit or within 25 ft. Consult Delfield if placementwill be greater than 25

ft. away. Remote condensing units may also be installed outdoors but require a U.L. listed enclosure which is supplied as an option from Delfield. Sufficient air circulation must be guaranteed at all times.

2.4 Electrical connections

A dedicated thermal-magnetic circuit breaker compliant with established regulations must be installed on the appliance power line.

Connected electrical cables must correspond to the technical data (as specified on electrical drawings provided by the installation technician).

Connect the earthing conductor to an efficient earthing system.

THE MANUFACTURER DECLINES ALL LIABILITY AND GUARANTEE OBLIGATIONS IN THE EVENT OF INJURY TO PERSONS OR DAMAGE TO EQUIPMENT AND OBJECTS DUE TO INCORRECT INSTALLATION AND/OR FAILURE TO COMPLY WITH STANDING INSTALLATION REGULATIONS.

Page 5
Image 5
Delfield T20C, T40, T5, T24C, T14D manual Installation, Avoid