T20C & T24C: Blast Chiller/Shock Freezer Remote Condensing Unit

13560 BTUH @ -32˚F, 90 amb, 104.4 Cond: 27,500BTUHDelfield®

T20C & T24C: Blast Chiller/Shock Freezer Remote Condensing Unit

39.00

39.00

Ambient Operating Limits: -20˚F to 120˚F

Note: The Delfield Blast Chiller/Shock Freezer is wired independently of the remote condensing unit. No interconnecting wiring is required between the blast chiller and the condensing unit. All condensing units have units have crankcase heaters. Condensing unit control systems are provided wired from the factory. Field Connection is made by connecting supply power to the compressor contactor.

Outdoor condensing unit applications require the use of an optional UL listed hood, delfield P/N CUHOOD, for protection from the elements. Water cooled units are not recommended for outdoor installation.

Interconnecting piping, curbs or other mounting methods and refrigerant are not included. Installation must be made by a qualified refrigeration technician. Piping runs of greater than 100 feet require consultaion with the factory.

 

 

T20C/T24C

 

 

 

 

 

 

 

 

 

 

Delfield

Model#: T20-T24CU

 

 

 

 

 

 

 

 

 

Refrigerant

 

 

404A

 

 

 

 

 

 

 

 

 

 

 

3 HP Compressor

 

 

 

Compressor and Capacity

13560 BTUH @ -32˚F, 90 amb, 104.4 Cond: 27,500BTUH

 

 

Compressor and wiring

 

 

@ -5˚, 90 amb

 

 

 

 

 

 

 

 

 

208/230V/60Hz/3Ph

 

 

 

 

 

 

 

 

Condensing Unit Wiring

Max Fuse Size: 35A

 

 

 

 

 

Max Circuit Ampacity:25.4A

 

 

 

 

 

 

 

 

High Pressure Switch

Set Point: 450 psig, 380 psig re-set

 

 

 

 

 

 

 

Control System

Low pressure switch

Set Point: 25psig, Range = 15in to 100psig

 

 

 

 

 

 

 

 

Oil Pressure Differential Switch

Sensotronic Oil Pressure Switch

 

 

 

 

 

 

 

Compressor Reliability

Crankcase Heater

65 watts

 

 

 

 

 

 

 

 

Condenser Capacity Control

Head Pressure Control Set at 84˚F, 185psig

 

 

 

 

 

 

 

 

Flow Control

Reciever Capacity

46lbs. @ 90% liquid refrigerant fill (31lbs. max

 

 

refrigerant charge)

 

 

 

 

 

 

 

 

 

 

 

 

 

Accumulator

Yes

 

 

 

 

 

 

 

 

Optional Outdoor Hood

Delfield

Model Number: CUHOOD

 

 

 

 

 

 

 

 

Shipping Weight

Condensing Unit

500 Lbs.

 

 

 

 

 

 

 

Outdoor Hood

100 Lbs.

 

 

 

 