Delfield T5 Example, Printing Out Stored Data Push-Button, Forced Ventilation Function, On/Off

Models: T14D T24C T5 T40 T20C

1 44
Download 44 pages 17.13 Kb
Page 17
Image 17
EXAMPLE:

6.5DISPLAYING THE THREE LATEST HACCP ALARMS (PUSH-BUTTON 10)

Set the machine to ON 6.6 PRINTING OUT STORED DATA PUSH-BUTTON (10) .

Press and hold down push-button 10 6.7 FORCED VENTILATION FUNCTION for more

HACCP

than five seconds (relative LED illuminates) to enter the alarm display function (date, hour and minute, alarm type and maximum temperature detected).

Every time the HACCP push-button is pressed, the

stored data are displayed.

 

EXAMPLE:

 

 

ALL.11

Display 15

Display 16

 

---

Str (start)

 

12

hr hour

 

29

min minutes

 

6

day days

 

8

mon month

 

03

yr year

 

End

end

 

13

Hr

 

21

min

 

6

day

 

8

mon

 

03

yr

 

75

maximum temperature

 

 

detected inside the cell

6.6 PRINTING OUT STORED DATA PUSH-BUTTON (10)

With the appliance in STAND-BY status, press and

hold down push-button 10 6.8 MANUAL DEFROSTING6.9 AUTOMATIC DEFROST CYCLESfor more than five seconds to print out the latest work cycle.

(With the appliance in STAND-BY status, press push-

button 10 6.10 PRINTER OPERATIONON/OFFonce to print out HACCP data). When the appliance is operating and the printer is on, the current cycle will be printed out.

6.7 FORCED VENTILATION FUNCTION

To activate this function when the appliance is

ONManual backgroundManual background , press push-button 12 Manual backgroundManual backgroundfor more than five seconds. The fan will continue to operate even when the cell door is open.

During forced ventilation, display 16 Manual backgroundManual backgroundwill show“dEF”.

6.8 MANUAL DEFROSTING

To activate this function when the appliance is

ONManual backgroundManual background press push-button 12Manual backgroundManual background (relative LED illuminates).

If conditions allow it (the temperature detected by the evaporator probe must be lower than the set point in the program parameters), the appliance

will perform a defrost cycle. Display 16Manual backgroundManual background will show “dEF”.

To immediately stop a defrost cycle, press push- button 12Manual backgroundManual background .

6.9 AUTOMATIC DEFROST CYCLES

The appliance automatically performs defrost cycles during storage. Three defrost cycles are performed during a 24-hour period(once every 8 hours).

The appliance automatically restarts once the defrost cycle has been completed.

6.10 PRINTER OPERATION

If you have to turn the instrument ON/OFF press

ON/OFF

If you have to feed the paper by hand press feed If you have to change the roll of paper, turn the instruments off, press the push bottom for opening the panel at the front of the instrument.

Slip the roll of paper into the lower side of the roller press feed as long as the roller drags the roll of paper.

Put the roll of paper into it’s box

Close the panel at the front of instruments.

Page 17
Image 17