Delfield T20C, T5, T24C, T14D manual T40 Installation and Assembly

Models: T14D T24C T5 T40 T20C

1 44
Download 44 pages 17.13 Kb
Page 41
Image 41
This should be done by a qualified refrigeration expert.

8.Thread electrical from the inside of the unit through the supplied hole in the top. Do not cut another hole to thread electrical.

9.Thread electrical wires through the top of control box and connect to controls.

Attach labeled electrical line to the corresponding labeled connector on the control panel.

10.Pipe remote condensing unit to the refrigerant lines coming out of the top of the cabinet.

T40 Installation and Assembly

This should be done by a qualified refrigeration expert.

Put the compressor system in a suitable, well aired place no farther than 25 feet. from cabinet.

11. Place interior probes

1.Interior Probe1: Place on wall next to the evaporator

2.Food Probe: Place in food product for monitoring

3.Interior Probe2: Place on opposite side of cabinet from evaporator 3/4 of the way to the top of the cabinet.

12.Unit must be plumbed with a P-trap to a drain for evaporator water discharge.

13.Place cam plugs in all cam holes to cover them. Press until seated in holes.

14.Install ramp and threshold onto the front of the outside of the door.

Page 41
Image 41
Delfield T20C, T5, T24C, T14D manual T40 Installation and Assembly, This should be done by a qualified refrigeration expert