INFORMATION
Service, Installation and Care Manual
T5, T14D, T20C, T24C, T40 Blast Chiller/Shock Freezers
INSTRUCTIONS
3. ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION
CONTENTS 1. GENERAL DOCUMENTATION
2. INSTALLATION
DESCRIPTION OF THE CONTROL PANEL
6. APPLIANCE FUNCTIONS
7. ALARM MANAGEMENT
8. MAINTENANCE AND CLEANING
1.5 General safety regulations
1. General Documentation
1.2 Installation
1.1. General information
2.1 Data plate information
2. Installation
Installation Clearance Requirements
2.2 Positioning
2.9 Appliance disposal
2.8 Safety and control systems
2.6 Condensate drainage connection
3.2 Operating tips
3. ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION
3.1 Shut-down procedures
3.2.1 Pre-cooling
HACCPPROGRAM
4. DESCRIPTION OF THE VERTICAL CONTROL PANEL
+38ο +38ο 0ο
HARD
4.1 PUSH-BUTTONS
PRE HEATING FUNCTION OF COMPRESSOR SUP
5. Programming and operating instructions
5.1 STARTING UP THE APPLIANCE only for T14D / T20C / T24C / T40
OPERATION
To select this cycle, press push-button
5.2 SOFT BLAST CHILLING BY TEMPERATURE pre-cooked, hot foods
to select the temperature mode LED 5A
to select the timer mode
The room temperature by pressing push button
The evaporator temperature by pressing push button
5.3 SOFT TIMED BLAST CHILLING
HARD
5.4 HARD BLAST CHILLING BY TEMPERATURE
5.5 HARD TIMED BLAST CHILLING
5.6 BLAST FREEZING BY TEMPERATURE
HACCP
5.7 TIMED BLAST FREEZING
ADDITIONAL FUNCTIONS
6. appliance functions
function. Display
6.4 PROGRAM STORAGE PUSH-BUTTON
6.7 FORCED VENTILATION FUNCTION
EXAMPLE
6.6 PRINTING OUT STORED DATA PUSH-BUTTON
6.8 MANUAL DEFROSTING
Cause Beeper Display Reset
7. Alarm Management
7.1 Storage of data/errors
Core probe alarm ALL
Input SW3 alarm ALL
Cause Beeper Display Reset Cause Effect Beeper Display Reset
Input SW2 ALL 05 door microswitch alarm
Reset
Excessive temperature alarm ALL
Cause Cause Cause Cause Effect Beeper Display Reset Cause Effect
Beeper Display Reset NB
Blackout alarm ALL
FAULT
INFORMATION ON ALARMS
List of other operating faults not indicated
SOLUTION
8.2 CLEANING THE CONDENSER
8. Maintenance and cleaning
8.1 GENERAL SAFETY REGULATIONS
8.3 CLEANING THE INTERNAL ROOM
Ship Weight
T5 Blast
Delfield
Chiller/Shock Freezer
Delfield
Ship Weight
T14D Blast Chiller/Shock Freezer
Sample Printout
Delfield
Blast Chiller/Shock Freezer
Ship Weight
T20C
Blast Chiller/Shock Freezer
T24C
Ship Weight
Delfield
Delfield
T40 Blast Chiller/Shock Freezer
Ship Weight
Sample Printout
13560 BTUH @ -32˚F, 90 amb, 104.4 Cond 27,500BTUH
T20C & T24C Blast Chiller/Shock Freezer Remote Condensing Unit
Delfield
T20-24CUW Remote Water Cooled Condensing Unit
Delfield
Condensing
Unit
Delfield
Freezer
Condenser Water Usage GPM
T40CUW Remote Water Cooled Condensing Unit
Delfield
T5/T14D refrigeration system schematic
9. wiring diagrams
Page
Page
Page
Page
T40 Air Deflection
T40 Installation and Assembly
Supplied Equipment List
Shields
T40 Installation and Assembly
T40 Installation and Assembly
Lock all side cams when the panel is in position. Insert
T40 Installation and Assembly
This should be done by a qualified refrigeration expert
Page
Page
Mt. Pleasant, MI
Model S/N Installation Date
Thank you for choosing Delfield
For a list of Delfield’s authorized parts depots