If the array status LED is solid or blinking amber:

a In the AMW, select the Summary tab, and click on Storage Array needs attention. Follow the listed procedures in the Recovery Guru(s) and wait for up to 5 minutes to check if the LED has turned blue. See "Recovery Guru" on page 235.

b If following the recovery guru procedures does not solve the problem, complete the following procedure to further troubleshoot the array.

c Turn off the host server as appropriate.

d Remove the RAID controller module and verify that the pins on backplane and RAID controller module are not bent. See "Removing a RAID Controller Module Blank" on page 209.

e Reinstall the RAID controller module and wait for 30 seconds. See "Installing a RAID Controller Module" on page 212.

f Check the RAID controller module status LED. g Replace the RAID controller module.

h Turn on the host server.

If the problem is not resolved, see "Getting Help" on page 265.

If the link status LEDs are not green, see "Troubleshooting Array and Expansion Enclosure Connections" on page 259.

a Turn off the server, storage arrays, and expansion enclosures.

b Reseat the RAID controller module and reconnect cables on the storage array and the server.

c Restart the storage array and wait until the array is fully booted. d Turn on the server.

e Check the link status LED. If the link status LED is not green, replace the cables.

If the problem is not resolved, see "Getting Help" on page 265.

Troubleshooting: Your Array

257

Page 257
Image 257
Dell MD3220, MD3200 owner manual 257