Item

Component

Function

 

 

 

18

SAS IN 3 port

Lights green when all four links are connected.

 

link/fault LED

Lights amber when one to 3 links are disconnected.

 

 

 

 

Off when all links in the port are disconnected or cable is

 

 

disconnected.

19

Management

Lights green when ethernet connection is operating at 1000

 

port speed LED

Mbps.

 

 

Lights amber when ethernet connection is operating at 100

 

 

Mbps.

 

 

Off when ethernet connection is operating at 10 Mbps or is

 

 

not active.

20

Management

Lights green when ethernet connection is active.

 

port activity LED

Off when ethernet connection is not active.

21

Management

Provides a 100/1000 Mbps Ethernet connection for out-of-

 

port Ethernet

band management of the enclosure.

 

connector

 

 

 

 

RAID Controller Module—Additional Features

Battery Backup Unit

Each RAID controller contains a two-cell Lithium ion nanopolymer battery backup unit (BBU). It provides power to the RAID controller module in the event of a power outage. For information on removing and installing the BBU, see "RAID Controller Module Backup Battery Unit" on page 214.

NOTE: For virtual disks, the RAID controller firmware changes the data cache setting based on the state of the battery. If the battery is missing or does not have sufficient charge, the controller flushes the cache and sets the write cache attribute to Write Through for all virtual disks. When the battery is replaced, Write Back is re-enabled.

34

Planning: RAID Controller Modules

Page 34
Image 34
Dell MD3200, MD3220 owner manual RAID Controller Module-Additional Features, Battery Backup Unit, Component Function