Table 4-1.

RAID Controller Physical Disk States (continued)

 

 

 

 

 

Status

Mode

Description

Physical Disk

 

 

 

Status LED

 

 

 

 

Pending

Assigned,

A Self-Monitoring Analysis and

Green flashing

Failure

Unassigned,

Reporting Technology (SMART) error

(500 ms), Amber

 

Hot Spare in

is detected on the physical disk in the

(500 ms), and Off

 

use, or Hot

indicated slot.

(1000ms)

 

Spare standby

 

 

Offline

Not applicable

The physical disk has either been spun

Green flashing

 

 

down or had a rebuild aborted by user

(3000 ms), Amber

 

 

request.

(3000 ms), and

 

 

 

Off (3000ms)

Identify

Assigned,

The physical disk is being identified.

Green flashing

 

Unassigned,

 

(250 ms)

 

Hot Spare in

 

 

 

use, or Hot

 

 

 

Spare standby

 

 

N/A

N/A

The indicated slot is empty, or the

 

 

 

array cannot detect the physical disk.

 

 

 

 

 

If a disk drive rebuild fails because of a source drive failure or because the drive is too small, the MDSM reports a failure of the physical disk even though the LED state on the drive indicates the rebuild was aborted (green for 3 seconds, amber for 3 seconds, then off for 3 seconds).

Self-Monitoring Analysis and Reporting Technology

SMART monitors the internal performance of all physical disk components to detect faults indicating the potential for physical disk failure. SMART uses this information to report whether failure is imminent so that a physical disk can be replaced before failure occurs. The storage array monitors all attached drives and notifies you when a predicted failure is reported by a physical disk.

Virtual Disks and Disk Groups

When configuring a storage array, you must:

1Organize the physical disks into disk groups.

2Create virtual disks within these disk groups.

Planning: MD3200 Series Storage Array Terms and Concepts

39

Page 39
Image 39
Dell MD3220, MD3200 owner manual Self-Monitoring Analysis and Reporting Technology, Virtual Disks and Disk Groups