Dell MD3220 Power Supply and Cooling Fan Features, Drive-Status Indicator Pattern Condition

Models: MD3220 MD3200

1 272
Download 272 pages 61.39 Kb
Page 29
Image 29

Drive-Status Indicator Pattern

Condition

Off

Steady green

Green flashing (On 250 ms, Off 250 ms) Green flashing (On 400 ms, Off 100 ms) Amber flashing (On 150 ms, Off 150 ms)

The physical disk is:

not yet discovered by the host server

is spun down for removal

not supported for the RAID controller module or is not in the physical disk slot

NOTE: The drive status indicator remains off until all hard drives are initialized after system power is turned on.

Drives are not ready for insertion or removal during this time.

Physical disk is online

Physical disk is being identified

Physical disk rebuilding

Physical disk failed

Flashing green, amber, and Off (green On

Physical disk failure predicted (SMART)

500 ms, amber On 500 ms, Off 1000 ms)

 

Flashing green, amber, and Off (green 3

Physical disk rebuild aborted

seconds, amber 3 seconds, and Off 3

 

seconds)

 

 

 

Power Supply and Cooling Fan Features

The MD3200 Series storage array includes two integrated, hot-swappable power supply/cooling fan modules. Both modules must be installed to ensure proper cooling. The system requires at least one of the cooling fans to function to avoid overheating.

A power supply/cooling fan module can be replaced without powering down the system. For information on removing and installing the modules, see "Power Supply/Cooling Fan Module" on page 216.

CAUTION: A power supply/cooling fan module can be removed from a powered- on enclosure for a maximum period of 5 minutes. Beyond that time, the system may automatically shut down to prevent damage.

Planning: About Your Storage Array

29

Page 29
Image 29
Dell MD3220, MD3200 owner manual Power Supply and Cooling Fan Features, Drive-Status Indicator Pattern Condition