Table 7-1. System Does Not Boot

Likely Causes to Check

Corrective Actions

 

 

Boot Mode, Boot Sequence,

1 At system startup, when the Dell POST screen

and/or Boot Sequence Retry are

 

appears, press <F2> to enter the Dell Inc.

set incorrectly

 

PowerEdge BIOS screen.

 

2

Scroll to Boot Settings. Press <Enter> and

 

 

make sure that Boot Mode is set to BIOS.

 

3

Scroll to Boot Sequence. Press <Enter> and

 

 

make sure that Hard drive C: (* PERC

 

 

S100 adapter or PERC S300 adapter) is

 

 

the first device listed.

 

 

* The variable text displayed here might be:

 

 

Embedded SATA 1, Slot 1, or Integrated

 

 

SAS.

 

4

Scroll to Boot Sequence Retry. Make sure

 

 

that the setting is Enabled.

 

5

Press <Esc> to exit and continue booting.

 

NOTE: If changes are made at the Dell Inc.

 

PowerEdge BIOS screen, a dialog box appears and

 

asks you to save your changes and then exit.

 

 

Bootable virtual disk is in a

1 Press <Ctrl><Alt><Del> to restart.

failed state

2 After the system restarts, press <Ctrl><R>.

 

 

Check the status of the bootable virtual disk at the

 

 

Virtual Disk field, or by highlighting View

 

 

Virtual Disks Details and pressing

 

 

<Enter>.

 

3

Check for missing or offline physical disks.

 

The boot order is incorrect for a 1 When prompted at system startup, press

bootable virtual disk

 

<Ctrl><R> to access the PERC Virtual Disk

 

 

Management utility.

 

2

Check Virtual Disks and make sure that the

 

 

bootable virtual disk is the first virtual disk listed.

 

3

As required, use the Swap Two Virtual

 

 

Disks option to reposition the virtual disks.

62

Troubleshooting

Page 62
Image 62
Dell (PERC) S100, PERC S300 manual Boot Mode, Boot Sequence