Table 7-7. Other Errors Appearing on the BIOS

Issue

Likely Causes to Check Corrective Actions

The RAID 0 goes

Faulty physical disk

offline and the RAID 1

 

becomes degraded in a

 

PowerEdge R210

 

system with two drives.

 

1 Boot system into CTLR-R and replace faulty drive.

2 Delete the failed RAID 0 and then create a new RAID 0. Now RAID 0 is optimal and RAID 1 is still degraded.

3 Install OS on the RAID 0 and backup RAID 1.

4 Delete and Recreate RAID 1 and restore backup data.

When attempting to

DUPs are not

Use the DOS utilities

update system

supported.

 

backplane firmware

 

 

and or Hard drive

 

 

firmware using DUPs

 

 

the updates fail.

 

 

 

 

 

eSata devices appear in

Issue with the physical

Remove the devices from eSata port

Ready state in CTLR-R

connection

and plug them into the chassis.

 

 

NOTE: eSATA devices are blocked

 

 

from virtual disk creation.

 

 

 

During CTRL-R,

The function is not

Remove all physical disks except for

S100/S300 do not

supported.

the last one(s) added. Then proceed

display greater than

 

with deleting the virtual disks that

eight Virtual Disks.

 

are not needed. Remember to take

 

 

account of the virtual disks that are

 

 

currently being used.

 

 

 

Unable to delete

The function is not

Remove all physical disks except for

Virtual Disks when

supported.

the last one(s) added. Then proceed

there are more than

 

with deleting the virtual disks that

eight Virtual Disks

 

are not needed. Remember to take

present in the system.

 

account of the virtual disks that are

 

 

currently being used.

 

 

 

Virtual disk rebuild

Rebuild is not

Boot to a supported OS. Rebuild

status while during

supported in Ctrl-R.

starts. To view rebuild status, install

CTLR-R

 

a supported storage application.

Troubleshooting

69

Page 69
Image 69
Dell PERC S300, (PERC) S100 manual From virtual disk creation