58
RAID Configuration and Management
Rescanning Disks
This option enables you to rescan all channels and detect new or removed
physical disks or virtual disks.
To perform a rescan, select
Rescan Disks
from the
Main Menu
field
and press <Enter>. (The activity indicator, in the information field at the
top of the window, spins while the physical disks are being polled).
•The
Rescan Disks
option rescans all the channels, searches for new or
removed physical disks, and re-reads the configuration information from
each physical disk.
NOTE:
Sometimes when a physical disk has failed, it can be brought online
through a rescan.
Controller Options
The Controller Options feature enables you to select INT 13 boot support
and select whether the boot process pauses when an error occurs. The boot
process pauses when Pause if... is enabled and a virtual disk becomes
Degraded or has Failed. Press <Enter> to continue booting.
View the error message on the window. If Pause... is OFF, the error
message is displayed briefly, but the system continues to boot.
1
At the
Main Menu
field, use the arrow key to select
Controller
Options
. Press <Enter>.
2
At the
Controller Options
field,
use the up or down arrow keys to
scroll to the desired controller option. See Table6-4.
3
When finished, press <Esc> to return to the main window.
Table 6-4. Controller Options
Controller Option Description How to Operate
INT13 Boot Support Determines whether the BIOS
installs INT 13 support
(physical disk seek, read, and
write operations for a PERC
S100 adapter or PERC S300
adapter).
Press <Enter> to
toggle between ON
and OFF.
A5_bk0.book Page 58 Thursday, February 10, 2011 8:34 PM