Troubleshooting
67
Table 7-5. Warning Messages: Dell Inc. PERC S100 or S300 Adapter BIOS
(continued)
Warning Message Corrective Action
WARNING: Found
virtual disks
that are
Degraded and
Failed
This warning message appears when multiple virtual disks are
in Degraded and Failed state and Pause if Degraded or
Pause if Failed are set to ON at the PERC Virtual Disk
Management utility.
The following message appears after the warning is displayed:
--- Press <Enter> to continue, or <Ctrl><R>
to enter setup ---
Press <Enter> to allow the operating system to continue its
boot, or press <Ctrl><R>
to enter into the
PERC Virtual Disk
Management
utility to investigate the cause of the
Degraded
and
Failed
virtual disks.
NOTE:
A boot virtual disk that is in a Failed state prevents the
operating system from booting.
To investigate the cause, check for the following:
• Whether the virtual disk is in
Degraded
status because one of
the physical disks of a RAID 1 or RAID 5 virtual disk has
failed, or one of the physical disks of a RAID 10 virtual disk
has failed.
Press <Ctrl><R>
and verify if the physical disks are offline
or missing. Remove and replace a failed physical disk. A
second physical disk failure could cause a
Degraded
virtual
disk to change to
Failed
status.
• Whether the virtual disk is in a
Failed
status because one or
more of the physical disks have failed.
Press <Ctrl><R>
and verify if the physical disks are offline
or missing. Remove and replace the failed physical disk or
disks.
A5_bk0.book Page 67 Thursday, February 10, 2011 8:34 PM