Dell R720XD owner manual Error Code

Models: R720XD R720

1 162
Download 162 pages 54.9 Kb
Page 146
Image 146

Error Code

Message Information

 

 

AMP0302

Message

The system board <name> current is greater than the upper warning

 

 

 

threshold.

 

Details

System board <name> current is outside of the optimum range.

 

Action

1.

Review system power policy.

 

 

 

 

2.

Check system logs for power related failures.

 

 

3.

Review system configuration changes.

 

 

4.

If the issue persists, see Getting Help.

AMP0303

Message

The system board <name> current is greater than the upper critical

 

 

 

threshold.

 

LCD Message

System board <name> current is outside of range.

 

Details

System board <name> current is outside of the optimum range.

 

Action

1.

Review system power policy.

 

 

 

 

2.

Check system logs for power related failures.

 

 

3.

Review system configuration changes.

 

 

4.

If the issue persists, see Getting Help.

ASR0000

Message

The watchdog timer expired.

 

 

Details

The operating system or an application failed to communicate within

 

 

the time-out period.

 

Action

Check the operating system, application, hardware, and system event

 

 

log for exception events.

ASR0001

Message

The watchdog timer reset the system.

 

 

Details

The operating system or an application failed to communicate within

 

 

the time-out period. The system was reset.

 

Action

Check the operating system, application, hardware, and system event

 

 

log for exception events.

ASR0002

Message

The watchdog timer powered off the system.

 

 

Details

The operating system or an application failed to communicate within

 

 

the time-out period. The system was shut down.

 

Action

Check the operating system, application, hardware, and system event

 

 

log for exception events.

146

Page 146
Image 146