Dell SC1435 owner manual System Messages

Models: SC1435

1 132
Download 132 pages 63.73 Kb
Page 16
Image 16

Table 1-5. Diagnostic Indicator Codes (continued)

Code

Causes

Corrective Action

 

 

 

 

BIOS checksum failure

Ensure that all network connections are functioning

 

 

detected; system is in

properly. See ""Troubleshooting Your System" on

 

recovery mode.

page 67."

 

 

If the problem persists, see ""Getting Help" on page 95."

 

 

 

System Messages

System messages appear on the screen to notify you of a possible problem with the system. Table 1-6 lists the system messages that can occur and the probable cause and corrective action for each message.

NOTE: If you receive a system message that is not listed in Table 1-6, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Table 1-6. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! Node Interleaving

The memory configuration does not

Ensure that the memory modules are

disabled! Memory configu-

support node interleaving. The

installed in a configuration that

ration does not support

system will run but with reduced

supports node interleaving. See

functionality.

"Memory Module Installation

Node Interleaving.

 

Guidelines" on page 46. If the problem

 

 

 

 

persists, see "Troubleshooting System

 

 

Memory" on page 76.

 

 

 

Attempting to update

Remote Configuration request has

Wait until the process is complete.

Remote Configuration.

been detected and is being

 

Please wait...

processed.

 

 

 

 

BIOS Update Attempt

Remote BIOS update attempt

Retry the BIOS update. If problem

Failed!

failed.

persists, see "Getting Help" on page 95.

 

 

 

Caution! NVRAM_CLR jumper

NVRAM_CLR jumper is installed.

Remove the NVRAM_CLR jumper.

is installed on system

CMOS has been cleared.

See Figure 6-1 for jumper location.

board.

 

 

16

About Your System

Page 16
Image 16