Table
Code | Causes | Corrective Action |
|
|
|
| BIOS checksum failure | Ensure that all network connections are functioning |
| ||
| detected; system is in | properly. See ""Troubleshooting Your System" on |
| recovery mode. | page 67." |
|
| If the problem persists, see ""Getting Help" on page 95." |
|
|
|
System Messages
System messages appear on the screen to notify you of a possible problem with the system. Table
NOTE: If you receive a system message that is not listed in Table
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.
Table
Message | Causes | Corrective Actions | |
|
|
| |
Alert! Node Interleaving | The memory configuration does not | Ensure that the memory modules are | |
disabled! Memory configu- | support node interleaving. The | installed in a configuration that | |
ration does not support | system will run but with reduced | supports node interleaving. See | |
functionality. | "Memory Module Installation | ||
Node Interleaving. | |||
| Guidelines" on page 46. If the problem | ||
|
| ||
|
| persists, see "Troubleshooting System | |
|
| Memory" on page 76. | |
|
|
| |
Attempting to update | Remote Configuration request has | Wait until the process is complete. | |
Remote Configuration. | been detected and is being |
| |
Please wait... | processed. |
| |
|
|
| |
BIOS Update Attempt | Remote BIOS update attempt | Retry the BIOS update. If problem | |
Failed! | failed. | persists, see "Getting Help" on page 95. | |
|
|
| |
Caution! NVRAM_CLR jumper | NVRAM_CLR jumper is installed. | Remove the NVRAM_CLR jumper. | |
is installed on system | CMOS has been cleared. | See Figure | |
board. |
|
|
16