Desa LEP) (V)L36(ZNR, LZPR) Continued, Burner backfiring during com, Maintenance, page

Models: LEN) (V)L32(HP LHN) (V)L36(EN LHP) (V)L36(EP L32, L36 L36, L42, L32, L36, L36, L42 L32, L36, L32, L36, VL36, L42, L36, L42 LZPR) LEP) (V)L36(ZNR

1 44
Download 44 pages 7.35 Kb
Page 31
Image 31
Burner backfiring during com-

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner backfiring during com-

1.

Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 28) or

 

2.

Damaged burner

 

replace burner orifice

 

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame in front burner dur-

1.

Not enough air

1.

Check burner(s) for dirt

ing burner combustion

 

 

 

and debris. If found, clean

 

 

 

 

burner(s) (see Cleaning and

 

2.

Gas regulator defective

 

Maintenance, page 28)

 

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes and logs curing

 

hours of operation

 

 

 

 

 

Heater produces a whistling noise

1.

Turning control knob to HI

1.

Turn control knob to LO po-

when burners are lit

 

position when burners are

 

sition and let warm up for a

 

 

cold

 

minute

 

2.

Air in gas line

2.

Operate burners until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

 

 

 

or propane/LP gas company

 

3.

Air passageways on heater

3.

Observe minimum installa-

 

 

blocked

 

tion clearances (see pages 9

 

4.

Dirty or partially clogged

 

through 11)

 

4.

Clean burners (see Cleaning

 

 

burner orifice(s)

 

and Maintenance, page 28) or

 

 

 

 

replace burner orifice(s)

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. turn into white

 

cleaners or similar products

 

 

powder residue

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 7)

115254-01A

www.desatech.com

31

Page 31
Image 31
Desa LEP) (V)L36(ZNR, LZPR), LHP) (V)L36(EP, LEN) (V)L32(HP Continued, Burner backfiring during com, Maintenance, page