TROUBLESHOOTING
Continued
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
ODS/pilot lights but flame goes | 1. Control knob not fully | 1. | Press in control knob fully | |
out when control knob is re- |
| pressed in | 2. | After ODS/pilot lights, keep |
leased | 2. Control knob not pressed in | |||
|
| long enough |
| control knob pressed in 30 |
| 3. | Safety interlock system has |
| seconds |
| 3. | Wait one minute for safety in- | ||
|
| been triggered |
| terlock system to reset. Repeat |
| 4. | Equipment shutoff valve not |
| ignition operation |
| 4. | Fully open equipment shutoff | ||
|
| fully open |
| valve |
| 5. | Pilot flame not touching | 5. | A) Contact local natural or |
|
| thermocouple, which allows |
| propane/LP gas company |
|
| thermocouple to cool, caus- |
|
|
|
| ing pilot flame to go out. This |
| B) Clean ODS/pilot (see |
|
| problem could be caused by |
| Cleaning and Maintenance, |
|
| one or both of the following: |
| page 28) or replace ODS/pilot |
|
| A) Low gas pressure |
| assembly |
|
| B) Dirty or partially clogged |
|
|
|
| ODS/pilot |
|
|
| 6. | Thermocouple connection | 6. | Hand tighten until snug, then |
|
| loose at control valve |
| tighten 1/4 turn more |
| 7. | Thermocouple damaged | 7. | Replace pilot assembly |
| 8. | Control valve damaged | 8. | Replace control valve |
|
|
|
| |
One or both burners do not light | 1. Inlet gas pressure is too low | 1. | Contact local natural or pro- | |
after ODS/pilot is lit | 2. | Burner orifice(s) clogged |
| pane/LP gas company |
| 2. | Clean burner(s) (see Cleaning | ||
|
|
|
| and Maintenance, page 28) or |
| 3. | Mislocated crossover tube |
| replace burner orifice(s) |
| 3. | Contact qualified service person | ||
| 4. | Remoteselector in OFF position | 4. | Put remote selector in ON |
|
|
| position | |
| 5. | Wire disconnected from gas | 5. | See Wiring Diagram, page 33 |
|
| control |
|
|
|
| els Only) |
|
|
|
|
|
| |
Delayed ignition of one or both | 1. Manifold pressure is too low | 1. | Contact local natural or pro- | |
burners | 2. | Burner orifice(s) clogged |
| pane/LP gas company |
| 2. | Clean burner(s) (see Cleaning | ||
|
|
|
| and Maintenance, page 28) or |
| 3. | Mislocated crossover tube |
| replace burner orifice(s) |
| 3. | Contact qualified service | ||
|
|
|
| person |
30 | www.desatech.com |