INSTALLATION
Continued
We recommend that you install a sediment trap in supply line as shown in Figures 21 and 22, depend- ing on your model. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings (Variable
CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings
|
| CSA Design- |
| ||
|
| Certified Equipment | |||
Propane/LP | Shutoff Valve with | ||||
1/8" NPT Tap* | Approved | ||||
From External | |||||
|
| ||||
|
| Flexible | |||
Regulator |
|
|
| ||
|
|
| Gas Hose (if | ||
(11" W.C.** |
|
|
| ||
|
|
| allowed by | ||
to 14" W.C. |
|
|
| ||
|
|
| local codes) | ||
Pressure) |
|
|
| ||
|
|
|
| ||
Natural |
|
|
|
| |
From Gas |
|
|
|
| |
Meter (5" |
|
|
|
| |
W.C.** to |
|
| 3" Minimum | ||
10.5" W.C. |
|
| |||
Tee Cap | Pipe | Gas | |||
Pressure) | |||||
Regulator | |||||
| Joint | Nipple | |||
|
| ||||
|
| Sediment Trap |
| ||
Figure 21 - Attaching Flexible Gas Line to | |||||
Control Valve |
CSA
Approved | Propane/LP | |
Flexible | ||
- From External | ||
Gas Hose (if | ||
Regulator | ||
allowed by | ||
(11" W.C.** to 14" | ||
local codes) | ||
W.C. Pressure) | ||
|
| Natural - From |
| Gas Meter (5" |
3" Minimum | W.C.** to 10.5" |
| Pipe | Cap TeeW.C. Pressure) |
| Nipple | Joint |
Gas | Sediment Trap | |
Control |
|
|
Figure 22 - Attaching Flexible Gas Line to Control Valve
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater.SeeguidelinesunderCon- necting to Gas Supply, page 16.