Desa LHP) (V)L36(EP, LZPR) Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: LEN) (V)L32(HP LHN) (V)L36(EN LHP) (V)L36(EP L32, L36 L36, L42, L32, L36, L36, L42 L32, L36, L32, L36, VL36, L42, L36, L42 LZPR) LEP) (V)L36(ZNR

1 44
Download 44 pages 7.35 Kb
Page 29
Image 29
TROUBLESHOOTING

TROUBLESHOOTING

OBSERVED PROBLEM WARNING:Turnoffandunplugheaterandletcoolbeforeservicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

 

nected to ignitor cable

2.

Free ignitor cable if pinched

 

2.

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ig-

 

 

 

 

nitor to base panel of log set. Nut

 

 

 

 

is located behind base panel

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned

6.

Replace pilot assembly for

 

 

wrong or broken

 

remote-ready units; Replace

 

 

 

 

ignitor electrode for variable

 

 

 

 

manually controlled units

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

ment shutoff valve closed

 

equipment shutoff valve

no ignition

2. Control knob not in PILOT

2.

Turn control knob to PILOT

 

 

position

 

position

 

3.

Control knob not pressed in

3.

Press in control knob while in

 

 

while in PILOT position

 

PILOT position

 

4.

Air in gas lines when installed

4.

Continue holding down con-

 

 

 

 

trol knob. Repeat igniting

 

 

 

 

operation until air is removed

 

5.

Depleted gas supply (pro-

5.

Contact local propane/LP gas

 

 

pane/LP only)

 

company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 28) or

 

 

 

 

replace ODS/pilot assembly

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

correct

 

 

115254-01A

www.desatech.com

29

Page 29
Image 29
Desa LHP) (V)L36(EP, LZPR), LEN) (V)L32(HP, LEP) (V)L36(ZNR Troubleshooting, Observed Problem, Possible Cause, Remedy