Desa LEN) (V)L32(HP, LZPR), LHP) (V)L36(EP, LEP) (V)L36(ZNR, LHN) (V)L36(EN Connecting To Gas Supply

Models: LEN) (V)L32(HP LHN) (V)L36(EN LHP) (V)L36(EP L32, L36 L36, L42, L32, L36, L36, L42 L32, L36, L32, L36, VL36, L42, L36, L42 LZPR) LEP) (V)L36(ZNR

1 44
Download 44 pages 7.35 Kb
Page 16
Image 16
CONNECTING TO GAS SUPPLY

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Manual background WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

Manual background CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.

Manual background WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 35.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 20. Pointing the vent down protects it from freezing rain or sleet.

Manual background CAUTION:Useonlynew,black ironorsteelpipe.Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas vol- ume to heater. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21 or 22, page 17, depending on your model).

IMPORTANT: Install equipment shutoff valve in an accessible location.The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual background WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Propane/LP

External Regulator

Supply Tank

 

Vent Pointing Down

Figure 20 - External Regulator with Vent

 

Pointing Down

16

www.desatech.com

115254-01A

Page 16
Image 16