MONITORING

English

If the system is armed and it receives either an Instant alarm signal from a sensor or the entry delay time on a sensor has expired, the system shall enter the Alarm State for 8 minutes.

MONITORING

A call is immediately placed to the monitoring service. The CALL LED will flash to indi- cate a call is in process. If a different sensor becomes unsecured during the current 8-minute window, another call will be placed. If the cellular radio signal is not available, it is recommended to use a telephone connection as a back-up.

BASE UNIT

If the strobe and siren are enabled, they will be activated. The CALL LED will be solid when the call was successful. The CALL LED message will extinguish after 30 sec- onds.

EVENT LOG

As an alarm occurs, the event is recorded in the event log. The log will record the type of event, the date and time. To find details on the event log, see Review Event Log.

After operating in the Alarm State for 8 minutes, the system shall return to arming. To exit the Alarm State enter a valid user code or press the disarm BASE UNIT button on the Key Chain Remote.

Before proceeding, the system will display the alarm that occurred. See Faults for more information on viewing the fault, clearing the fault and resuming normal status.

ALARM CODES (BASE UNIT)

Display

Event

Unsecured device x txt

Unsecured

Tampered device x txt

Tamper

Unsecured base motion

Internal PIR trip

Unsecured base vibration

Internal vibration trip

System alarm

Start of alarm cycle (8 min.)

 

 

NOTE: Please refer to Cell Phone Text Message Codes in the Appendix.

INITIAL SETUP

Vibration

The Base Unit contains a vibration sensor. Mount the Base Unit in a location that is not subject to vibration during the armed state. If the system is armed and both the motion sensor and vibration sensor are activated, an alarm is sent instantly.

Heat

The motion detector inside the Base Unit is sensitive to heat. To prevent false alarms, avoid placing in direct or reflected sunlight, or near objects that can be heated quickly by sunlight. Do not place the Base Unit facing the windows. Do not place the unit near heating or cooling sources, like heater ducts, air conditioners, or space heaters.

DEWALT MOUNTING BRACKET (DS001)

The DEWALT Mounting Bracket (DS001) is recommended for mounting and to secure the Base Unit to a wall or corner. The Mounting Bracket must be purchased separately.

CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. This equipment is for indoor use only. Placement in outdoor conditions can damage the unit.

POWER AND TELEPHONE CONNECTION

The unit must be connected to a power source to begin set up. This will charge the internal battery. It is recommended that the Base Unit be connected to a telephone line to provide back-up in the event of cellular reception loss.

Power Connection

CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Use only DEWALT power supplies marked for use with this product. Other power supplies may damage the product.

NOTE: The battery will take up to 24 hours to charge completely. To avoid draining the battery, do not use an outlet that is controlled by a wall switch. The battery is designed to be a back-up source of power for up to 8 hours. If the monitoring serv- ice has been activated, the Base Unit will send a low battery message to the moni- toring servce approximately 1 hour before the battery is drained. If power is not restored within that remaining hour, the Base Unit will disarm and shut down.

Connecting the Equipment

Placement of the Base Unit

Physical Setup

PLACEMENT OF THE BASE UNIT

Height

The recommended height for the Base Unit is between 3' (.9m) to 6' (1.8m) off the floor. Any height outside of this range will decrease the sen- sitivity of the motion detector in the Base Unit. Be sure that the unit is placed at a height such that any person accessing the system can easily operate the keypad.

Edge

If using the Base Unit on a desk, shelf or any other fixed object, placing the unit near the edge will maximize the range of the motion detector.

SENSOR

RANGE

3' to 6'

(.9m to 1.8m)

IMPORTANT: After power has been restored, the Base Unit will not be armed.

EVENT LOGALARM CODES (BASE UNIT) C

B

A

D

 

1.

Connect the power supply connector (A) to the receptacle (B) in the back of the

 

Base Unit (C).

2.

Insert the 120V plug of the power supply (D) into the wall receptacle.

3.

The power light will indicate that the system has power.

 

IMPORTANT: After connecting the unit, the alarm system will not be active until

 

the initial setup is complete, the sensors are programmed and DEWALT customer

 

service registers the system.

 

IMPORTANT: If the unit is unplugged and not armed, the unit will go into standby

Direction

Face the Base Unit in a direction so that intruders move across the detection zone, rather than toward or away from the motion sensor in the Base Unit.

mode after 10 minutes. To return the unit to normal operation, press any key or

plug unit into a wall receptacle.