1.5 Post Mount

Mount the post base into the concrete before installing the operator.

The post mount installation will allow the operator to be mounted low enough to attach the gate bracket to the lower gate rail if desired.

Note: 2” thick gate Illustrated.

Gate

These measurements will work for standard or

Closed

convenience open models from 1.1 layout on page 10 ONLY.

 

 

 

 

 

 

90°

 

 

 

 

 

 

 

 

 

 

 

Open Gate

 

 

 

 

 

 

 

 

 

 

6”

 

Concrete

 

 

 

 

 

 

 

 

Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25.25”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Post Base

 

 

 

 

 

 

 

 

 

 

 

 

 

29”

 

 

 

 

 

 

10”

 

 

 

 

 

 

 

 

 

 

Conduit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable

Interconnection

Operator MUST be level.

Gate Bracket Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arm

 

 

3”

 

Low

 

High

 

 

 

 

 

 

 

 

 

Rotation Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volt

 

Volt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This distance can vary (6” minimum).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth of the concrete pad is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

determined by soil conditions and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

local building codes. Reinforced

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

concrete recommended.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18.5”

Run all conduit on the opposite side of the open gate.

1.6 Arm and Gate Bracket Installation

G Brackette

Gate Hinge Pivot Point

30” Crank Arm

Point arms towards gate bracket.

Crank Power Arm

 

Arm

Closed Gate

 

cting

 

onne

 

C

 

60”

 

 

Assemble arms as shown with the gate in the closed position. The elbow assembly’s flange MUST be on the opposite side of the gate in the closed position. This is the physical stop used to set the open and close limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arms MUST be level.

 

 

 

 

 

 

 

 

 

 

Top of Crank Arm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install gate

 

 

 

 

 

 

 

 

 

 

Elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3”

 

 

bracket to gate.

 

 

 

 

 

Flange

 

 

Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60” Connecting Arm

 

 

 

 

 

 

 

 

 

Gate Rail

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34”

 

 

 

 

 

 

 

 

Varies

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjust the locknut on the crank power arm so that it is snug against the washer, but will still allow the crank arm to rotate with little force. This is the operator’s manual release option when the crank arm is unlocked.

Do not secure the elbow assembly to the arms until the arms have been adjusted. (See next page).

Do not insert the locking pin or padlock into the crank arm. It will be installed after arms have been adjusted.

6050-065-L-11-08