SECTION 6 - MAINTENANCE AND TROUBLESHOOTING
Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks.
6.1 Maintenance
When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can be identified and corrected.
Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result in serious injury or death should they become entrapped in the gate.
When servicing this gate operator, always turn power OFF!!
Operator | Maintenance | Monthly Interval | |||
|
|
|
| ||
Component | 3 | 6 | 12 |
| |
|
| ||||
|
|
|
|
|
|
Alarm | Activate the primary (inherent) reverse system by blocking the |
|
|
|
|
| gate with a solid object. When the gate reverses, block the gate | ✓ |
|
|
|
| in the opposite direction prior to the limit being reached. The |
|
|
| |
| entrapment alarm should activate. Press the reset button to |
|
|
|
|
| silence the alarm. |
|
|
|
|
|
|
|
|
|
|
Arms | Check set screws and nuts. Check bushings for wear. |
| ✓ |
|
|
|
|
|
| ||
Batteries | If operator is equipped with optional DC open system, check the | ✓ |
|
|
|
| batteries for any leakage or loose connections. Batteries should |
|
|
| |
| be replaced every two years. |
|
|
|
|
|
|
|
|
|
|
DC Open System | If operator is equipped with optional DC open system, check to | ✓ |
|
|
|
| be sure the system opens the gate upon loss of AC power. |
|
|
| |
Drive Belt | Check for alignment, tightness and wear. | ✓ | ✓ |
|
|
|
|
|
| ||
Fire Dept. | Check emergency vehicle access device for proper operation. |
|
|
| |
Gate | Inspect for damage. Check gate hinges for wear and grease if |
| ✓ |
|
|
| necessary. |
|
|
| |
Gear | Inspect for wear. Grease if necessary. Use only EP Molybdenum |
| ✓ |
|
|
| Disulfide (Moly D) grease (DoorKing P/N |
|
|
| |
Grease | Main shaft zert fitting. |
| ✓ |
|
|
|
|
| |||
Primary Reverse System | Check that the gate reverses on contact with an object in both | ✓ |
|
|
|
| the opening and closing cycles. |
|
|
| |
| Adjust the reversing sensor if necessary. |
|
|
| |
| ✓ |
|
|
| |
Loop(s) | Check vehicular reverse and shadow loops for proper operation. |
|
|
| |
|
|
| |||
Release | Check manual release for proper operation. | ✓ |
|
|
|
|
|
| |||
Secondary Reverse Device | Check secondary (external) reverse device(s) stop or reverse the | ✓ |
|
|
|
| gate when activated. |
|
|
| |
Worm Gear | Inspect for wear and proper alignment. |
| ✓ | ✓ |
|
|
|
|
| ||
Complete System | Complete check of gate and gate operating system. |
|
|
|