SECTION 6 - MAINTENANCE AND TROUBLESHOOTING

Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks.

6.1 Maintenance

When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can be identified and corrected.

Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result in serious injury or death should they become entrapped in the gate.

When servicing this gate operator, always turn power OFF!!

Operator

Maintenance

Monthly Interval

 

 

 

 

Component

3

6

12

 

 

 

 

 

 

 

 

 

Alarm

Activate the primary (inherent) reverse system by blocking the

 

 

 

 

 

gate with a solid object. When the gate reverses, block the gate

 

 

 

 

in the opposite direction prior to the limit being reached. The

 

 

 

 

entrapment alarm should activate. Press the reset button to

 

 

 

 

 

silence the alarm.

 

 

 

 

 

 

 

 

 

 

Arms

Check set screws and nuts. Check bushings for wear.

 

 

 

 

 

 

 

Batteries

If operator is equipped with optional DC open system, check the

 

 

 

 

batteries for any leakage or loose connections. Batteries should

 

 

 

 

be replaced every two years.

 

 

 

 

 

 

 

 

 

 

DC Open System

If operator is equipped with optional DC open system, check to

 

 

 

 

be sure the system opens the gate upon loss of AC power.

 

 

 

Drive Belt

Check for alignment, tightness and wear.

 

 

 

 

 

 

Fire Dept.

Check emergency vehicle access device for proper operation.

 

 

 

Gate

Inspect for damage. Check gate hinges for wear and grease if

 

 

 

 

necessary.

 

 

 

Gear

Inspect for wear. Grease if necessary. Use only EP Molybdenum

 

 

 

 

Disulfide (Moly D) grease (DoorKing P/N 2600-770)

 

 

 

Grease

Main shaft zert fitting.

 

 

 

 

 

 

Primary Reverse System

Check that the gate reverses on contact with an object in both

 

 

 

 

the opening and closing cycles.

 

 

 

 

Adjust the reversing sensor if necessary.

 

 

 

 

 

 

 

Loop(s)

Check vehicular reverse and shadow loops for proper operation.

 

 

 

 

 

 

Release

Check manual release for proper operation.

 

 

 

 

 

 

Secondary Reverse Device

Check secondary (external) reverse device(s) stop or reverse the

 

 

 

 

gate when activated.

 

 

 

Worm Gear

Inspect for wear and proper alignment.

 

 

 

 

 

 

Complete System

Complete check of gate and gate operating system.

 

 

 

32