3.2 DIP-Switch SW 1 Settings
The two
|
|
| SW 1 (Top 8 Switches) | |
|
|
|
| |
Switch | Function | Setting | Description | |
|
|
|
| |
|
| Relay activates when gate is open. | ||
1 and 2 | Relay | Relay activates when gate is not closed. | ||
Relay activates when gate is opening and open. | ||||
|
| |||
|
| Relay activates when gate is opening and closing. | ||
|
|
|
| |
3 | Open loop | OFF | Terminal 12 is the output from the open detector. | |
Logic Output | ON | Terminal 12 is an open input. | ||
| ||||
4 | OFF | |||
Timer | ON | |||
| ||||
5 | Slide Gate | OFF | OFF for Slide gate operator. | |
Swing Gate | ON | ON for Swing gate operator. | ||
| ||||
6 | OFF | OFF when using a | ||
Single Button | ON | ON when using a single button control. | ||
| ||||
7 | Dual Operators | OFF | Switch must be OFF when | |
Single Operator | ON | Switch must be ON for single operator. | ||
| ||||
8 | Tamper Protect | OFF | Tamper protect is OFF. | |
ON | Tamper protect is ON. | |||
|
| |||
|
|
|
|
Switches
Switch 3 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT port will be sent directly to the microprocessor to open the gate, or if the output is directed to Terminal 4 where it can then be connected to other input terminals.
Switch 4 Turns the auto close timer on or off. Maximum time that the close timer can be set for is approximately 23 seconds.
Switch 5 This switch enables the 4502 circuit board to be used in either a swing gate or slide gate application. Some older DoorKing slide gate operators did use the 4501 circuit board for control. This switch is here to allow use of this board on these older products.
Switch 6 Sets up the circuit board for single button or
Switch 7 Sets up the circuit board for single or primary / secondary (dual) gate operation.
Switch 8 If the gate is forced open, the