3.3 DIP-Switch SW 2 Settings
|
|
| SW 2 (Bottom 8 Switches) | |
Switch | Function | Setting | Description | |
| Primary | OFF | Opening direction of arm using OFF setting. | |
| Gate opens | |||
1 | Operator | |||
| ||||
Opening |
|
| ||
|
|
| ||
| Direction | ON | Opening direction of arm using ON setting. | |
|
| Gate opens clockwise. | ||
|
|
| ||
| Secondary | OFF | Opening direction of arm using OFF setting. | |
| Gate opens | |||
| Operator | |||
2 |
| |||
Opening |
|
| ||
|
| Opening direction of arm using ON setting. | ||
| Direction | ON | ||
|
| Gate opens clockwise. | ||
|
|
| ||
3 | OFF | Normal operation. | ||
ON | ||||
|
| |||
|
|
| Switch is OFF when both primary and secondary operator motors are powered | |
|
| OFF | from main terminals 4 and 5. Applies to operators originally manufactured with | |
4 | Motor Control |
| 4501, Rev O boards or lower). | |
| Switch is ON when secondary operator motor is powered from the secondary | |||
|
| ON | ||
|
| motor terminals. Applies to operators manufactured with 4501, Rev P boards and | ||
|
|
| higher, and all 4502 boards. | |
5 | Reverse Loop | OFF | Terminal 15 is a normal Reverse input. | |
Shadow Loop | ON | Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle. | ||
| ||||
6 | Gate Overlap | OFF | Primary and secondary operators start at the same time. | |
ON | Secondary operator starts | |||
|
| |||
7 | Not Used | OFF | Leave in the OFF position. | |
8 | Not Used | OFF | Leave in the OFF position. |
Switch 1 Sets direction of the primary operator so that the operator cycles open upon initial power up and open command. If the operator begins to cycle close upon initial power up and open command, turn power off and change the setting on this switch.
Switch 2 Sets direction of the secondary operator so that the operator cycles open upon initial power up and open command. If the operator begins to cycle close upon initial power up and open command, turn power off and change the setting on this switch.
Switch 3 This switch is a
Do not run this test with the operator connected to the gate.
Switch 4 This switch applies high voltage motor power to the secondary operator motor terminal located at the top of the board. If a primary / secondary system is in use, this switch should be ON and the secondary motor wires connected to the secondary operator motor terminal. For single gate applications, this switch can be turned OFF.
Switch 5 This switch sets the input at Terminal 15 to act as a normal reverse input or to act as a shadow input. A shadow input will only hold the gate operator in the open position once it is in the full open position. A shadow input will not reverse the direction of the gate operator once it begins its close cycle.
Switch 6 Used in primary / secondary applications, turning this switch ON will cause the start of the primary operator to be delayed
Switches 7 and 8 Spare switches, leave in the OFF position.