Dynaudio pmn manual Analog Setup, 5.1 Dig/6 - Master, Setups

Models: pmn

1 60
Download 60 pages 63.12 Kb
Page 15
Image 15
6.1 Analog Setup

Air_US_rev_111.qxd 16-12-2004 14:16 Page 13

SETUPS

To set a Master 5.1 Dig/6 - MasterManual backgroundManual backgroundManual background monitor asManual backgroundManual backgroundManual backgroundManual background System Controller Manual backgroundManual background the TC LinkManual background button on the rear Manual backgroundManual backgroundManual background

panel MUST be in out-position.

Channels must be connected as follows:

-Left channel to Left Input on Left monitor.

-Right channel to Right Input on Left monitor.

-Center channel to Left Input on Center monitor.

-LFE channel to Right Input on Center monitor.

-Left Surround channel to Left Input on Left Surround monitor.

-Right Surround channel to Right Input on Left Surround monitor.

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

6.1 Analog Setup

This illustration shows how to connect a 6.1 Analog setup

Left is set as System Controller by leaving out the TC Link button on the rear panel.

Left monitor receives both the Left and Right signal. The Right monitor is fed via the TC LINK RJ-45 connection form Left to Right.

Center monitor receives both Center and LFE signal. The LFE monitor is fed via the TC LINK RJ-45 connection from Center to LFE.

Left Surround monitor receives both LS and RS signal. The RS monitor is fed via the TC LINK RJ-45 connection from LS to RS.

The Center Surround monitor receives only Center Surround signal.

Center Chain: From software 1.10 it is possible to connect one or more Center Chain monitors.

With Bass-management “off” only the LFE signal is fed to the Sub.

With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote and/or AIR Soft, can be connected to any available TC LINK Out connection.

5.1 Dig/6 - Master

This is a 5.1 digital setup with Bass Management as an option. The setup requires one Master monitor with the optional Digital AES/EBU Input Card installed, four Slave monitors (or Masters set as Slave) and one Sub.

Center monitor is set as System Controller by leaving out the TC Link button on the rear panel.

Center monitor receives all 6 channels on the three AES/EBU connections.

-Center and LFE on the monitors Digital IN connection.

-Left and Right on the I/O cards Digital IN no. 2.

-LS and RS on the I/O cards Digital IN no. 3.

Right, Left, Sub, LS and RS receives signal via TC LINK RJ-45 connections from the Center Master monitor.

Clock MUST be sent on the AES connection feeding Center/LFE channels (or on BNC).

With Bass-management “off” only the LFE signal is fed to the Sub.

With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote and/or AIR Soft, can be connected to any available TC LINK Out connection.

13

Page 15
Image 15
Dynaudio pmn manual Analog Setup, 5.1 Dig/6 - Master, Setups