Dynaudio pmn manual Calibrate - AIR BASE, Chained monitors, Air Soft

Models: pmn

1 60
Download 60 pages 63.12 Kb
Page 52
Image 52
Calibrate - AIR BASE

Air_US_rev_111.qxd 16-12-2004 14:18 Page 50

AIR SOFT

Calibrated Level

Level calibration of the selected monitor.

Relative Level

Preset volume for the selected monitor relative to the calibrated and global volume.

Use Parametric EQ

This will be marked if the Parametric EQ is activated via the PC-IP. Bass and Treble settings will be disabled.

Bass/Treble Range: -6dB to +6dB

Bass and Treble adjustment for the selected monitor. These handles are not available when the Parametric EQ is activated via PC-IP.

Mute

Press to mute the selected monitor.

Solo

Press to solo the selected monitor.

Pink Noise

Press to generate Pink Noise in the selected monitor.

Calibrate - AIR BASE

Mute

Solo

Pink Noise

Via this Calibrate screen, parameters and settings for the Subwoofers are controlled.

The screen is accessed via the Main Screen by holding the cursor above the desired Sub and selecting the hammer icon.

Phase Range: 0-180°

To time-compensate if the Sub is not placed according to the ITU 775 recommendations. There are individual Phase settings for each of the Bass Management Cross-over frequencies. Once set, these are stored as Global settings.

Polarity

Range: 0 or 180 deg.

Mark to activate.

Calibrated Level

Level calibration of the selected monitor.

Relative Level

Preset volume for the selected monitor relative to the calibrated and global volume.

LFE Gain Range: 0 to 14dB

With this parameter you can boost the gain of the LFE channel.

LFE Low Pass Filter

Mark to activate.

Mute

Press to mute the selected Sub.

Solo

Press to solo the selected Sub.

Pink Noise

Press to generate Pink Noise in the selected Sub.

Chained monitors

If several monitors are chained on the same task (e.g. LSur-LSChain) a dropdown menu will be present as illustrated below.

To calibrate a chained monitor simply select from the list.

Chained monitors will also be indicated in the Main screen.