DELAY IN SYSTEM & ERROR MESSAGES ETC.

Air_US_rev_111.qxd 16-12-2004 14:18 Page 56

DELAY IN SYSTEM & ERROR MESSAGES ETC.

Sample Rate

Digital Input

 

Analog Input *)

 

 

 

 

 

 

 

 

 

(AES or WC In)

Converter

Samples @

msec

centimeter

Samples @

msec

centimeter

kHz

kHz

Input Rate

 

 

Converter Rate

 

 

32.00

64.00

93.00

2.91

100

73.00

1.14

39

44.10

88.20

68.00

1.54

53

73.00

0.83

28

48.00

96.00

40.00

0.83

29

73.00

0.76

26

64.00

64.00

34.00

0.53

18

73.00

1.14

39

88.20

88.20

34.00

0.39

13

73.00

0.83

28

96.00

96.00

34.00

0.35

12

73.00

0.76

26

*): In Analog Input mode without WC Input selected, the system runs on the Master monitor's own 96kHz clock.

Error messages etc.

"!" as "96 kHz Center!”

The "!" indicates that the monitor is not connected to the network. The volume is then automatically set to -50 dB for the monitor not recognized.

"+" as "96 kHz L Front+":

The "+" indicates that the monitor you are looking at is the System Controller.

>> A-Input Lo <<

This is displayed in analog setups only and indicates that the Input level has been detected to be between -60dB and -20dB for a period longer than 3 minutes. This is a hint to turn up the Analog Input Gain

Analog Input gain range:

+9dBu, +15dBu, +21dBu or 27 dBu.

>> A-Input Hi <<

This is displayed in analog setups only and indicates that an Input level near 0dB is detected. (peaks in 2 sec. above -1 dB). This is a warning and you should turn down the Analog Input gain range:

+9dBu, +15dBu, +21dBu or 27 dBu.

>> PSU error <<

Displayed if the power supplies fails. The power will be turned off and the monitor cannot operate. Contact the Service Department.

<Locked>

Displayed when a parameter is locked by the installer software and cannot be changed.

Parameter lock can only be unlocked with AIR IP software.

Standby

Displayed when no Input signal has been detected for more than 30 min. below -65 dB. The Amplifier is turned off. Standby mode is released as soon a signal level above -65dB has been detected.

>> Power save <<

Displayed when no signal has been detected on all monitors on network for more than 2½ hours. Power is turned off. Exit this mode by pressing any key on system controller or adjusting volume from remote.