Dynaudio pmn manual System Setup, Air Soft, Calibrate - Main Monitors, Monitor assignment

Models: pmn

1 60
Download 60 pages 63.12 Kb
Page 51
Image 51
Monitor assignment

Air_US_rev_111.qxd 16-12-2004 14:18 Page 49

AIR SOFT

During Software upload various messages could be displayed:

Example:

In a 5.1 AIR setup you are uploading monitor software to the entire system. As there are separate software files for monitors and subs the following message should appear.

“5 AIR monitors updated successfully”

-meaning the AIR monitors are updated but no software has be accepted by the connected sub.

If a monitor has lost connection during transfer it will not be counted but the software upload continues.

If the message: “Failed to update AIR monitors” - is displayed, some of the monitors have reported an error during software upload. This could be caused by communication errors. Please retry.

OK

Press to exit screen and execute Autodetect command if marked.

Monitor assignment

Task

Press monitor symbol to activate pink noise test-tone.

Then select task for the monitor now playing the noise. Serial number and type will be indicated.

A monitor marked with an exclamation mark indicates that an “unknown” monitor has been detected.

Scan System

Press the magnifying-glass to scan the entire system for connected units.

Save Settings

All settings except “preset settings” are saved to a back-up file.

Load Settings

Press and browse to select file to load.

Follow the instructions.

System Setup

Calibrate - Main Monitors

Configuration

Select your current setup.

Analog Gain

Range: 9dBu, 15dBu, 21dBu or 27dBu

Set to match analog Input gain to match the signal fed to the optional Analog Input card.

BNC Input BNC Sync On:

The monitor attempts to lock on the Word Clock BNC.

Mute

Solo

Pink Noise

Via the Calibrate screen, parameters and settings for the Main monitors are controlled.

The screen is accessed via the Main Screen by holding the cursor above the desired monitor and selecting the hammer icon.

Room position

Range: Neutral, Wall, Corner, Console, C. Wall or C. Corn Select according to the actual position of the monitor.

X Curve

Range: Off, X-Curve 1 or X-Curve-2

Two modifications of X-222 curve are available. See page 21.