Basic connections and settings

Capturing sound from an external ADAT device

fig.basic

OUTPUT

Optical cable

OPTICAL IN

Set the sampling

frequency

Connections

Connect an optical cable to the OPTICAL IN jack.

Sampling frequency select switch

Select either 44.1 kHz or 48 kHz.

Set this to the same sampling frequency as specified for your ADAT or recording software.

ADAT mode switch and external clock switch

fig.adat-sig

Simultaneously press the ADAT mode switch and external clock switch.

The PEAK/SIG/ADAT IN indicators will light orange simultaneously.

Press simultaneously

Lit (orange)

fig.adat-sig2

When audio signals are input from the ADAT to the UA-1000, the PEAK/ SIG/ADAT IN indicators will light green.

Lit (green)

*If the word clock input connector is connected, the word clock input connector will take priority for synchronization. In this case, the ADAT connected to the digital input connector must also be synchronized to the word clock.