Synchronization settings

ADAT Input mode

Simultaneously press the ADAT mode switch and the External Clock mode switch. The peak indicator will light in orange, and the UA-1000 will be in ADAT Input mode. The outputs will operate in the same way as in ADAT Output mode.

*If the word clock input connector is connected, the word clock input connector will take priority for synchronization. If the UA-1000 is operating in synchronization to the word clock, the ADAT compatible device connected to digital input must be synchronized to the word clock.

*Set the sampling frequency select switch and the sampling frequency setting of your software to 44.1 kHz or 48 kHz. If a setting other than 44.1 kHz or 48 kHz is selected, ADAT mode will not be available; pressing the ADAT mode switch will not cause the ADAT mode switch to light.

*If the external clock switch is blinking, synchronization has not been achieved. The UA-1000 will not be able to record or play back correctly. Please check the settings of the connected equipment.

Possible reasons for problems

The digital signal from the connected ADAT compatible device is not being received correctly.

If a word clock is being input to the word clock input connector in ADAT mode, the word clock signal is not being received correctly, or the sampling frequency of the word clock is not 44.1 kHz or 48 kHz.

*Turning off the power of the UA-1000 will not change the setting of this switch.

*The coaxial digital and analog input jacks will not be available.

fig.adat-off

While in ADAT Input mode, pressing the ADAT switch will exit

ADAT mode and enter External Clock mode.

fig.adat-ext-off

While in ADAT Input mode, pressing the External Clock mode switch will exit ADAT Input mode and enter ADAT Output mode.

42