System settings

Restoring the factory settings (Factory Reset)

fig.system

1.While simultaneously holding down the output volume select

switch and the STEREO/MONO select switch, turn on the

power.

The output volume select switch and the STEREO/MONO select

switch will blink.

Hold down simultaneously

and turn on the power

2.Press the STEREO/MONO select switch once again.

The output volume select switch and the STEREO/MONO select switch will blink faster, and then the direct monitor soft control switch (SOFT CTRL) will light.

(The operation will be cancelled if you press any LED switch other than the STEREO/MONO select switch.)

Once the direct monitor soft control switch (SOFT CTRL) has lighted, the output volume select switch and the STEREO/MONO select switch will go out.

The factory settings have now been restored.

Factory settings

Function

State

 

 

STEREO/MONO select switch

STEREO

Direct monitor soft control switch

On

ADAT

Off

EXT CLOCK

Off

Output volume mode

MAIN

*For details of the UA-1000's internal block structure when it is shipped from the factory, refer to “Block diagram” (p. 51).