PROGRAMMING

 

Table 4-5 Scan Function Screen Description (Continued)

 

 

Parameter

Description

 

 

Stop Timer

When Mode 2 or 3 above is programmed (priority scanning), this sets how often in seconds the priority channel

 

is checked while receiving a message on some other channel.

 

 

Resume

This sets the scan resume delay in seconds. This is the time that elapses before scanning resumes after a

Timer

message is received.

 

 

PWR ON

If this function is programmed “On”, scanning starts automatically when transceiver power is turned on. The

Scan

“Hanger Action” parameter in Table 4-2should also be programmed for “Scan” if power-on scan is used. If

 

scanning halts to transmit a message, the timer selected for Auto Reset parameter in the channel screen (see

 

Table 4-1)determines the delay before scanning resumes. See also Scan A/B function in Key Assign screen

 

(Table 4-2), “Scan” column in 2-Tone Code CH screen (Table 4-6),“Timer A/B” in Common screen

 

(Table 4-7), and “Fast/Slow Scan Timer” in Expert screen (Table 4-8).

 

 

Auto CH

The parameter is displayed only in the PMR (European) mode, and is used with the 5-tone option. If “On” is

Call

programmed, pressing the CALL key (1) starts scanning, (2) detects a non-busy channel, and (3) transmits the

 

5-tone codes.

 

 

Table 4-6 2-Tone Code Channel Screen Description

 

 

 

 

NOTE: Optional

 

 

 

 

2/5-Tone Module,

 

 

 

 

P.N. 585-7500-

 

 

 

 

026, is required to

 

 

 

 

utilize the two-

 

 

 

 

tone feature.

 

 

 

 

 

Parameter

 

Description

 

 

 

 

 

 

Rx Freq

Sets the frequencies for the first and second tones from 250-3300 Hz. The closest tone is selected.

1st/2nd

 

 

 

 

 

 

 

 

 

Group Call

Programs if the 1st or 2nd tone is used for the group code.

 

 

 

 

 

 

Text

Programs the text that is displayed when a matched 2-tone is received. The characters and other information

 

described for “TEXT” in Table 4-1also applies to this text.

 

 

 

 

 

 

Bell

Selects the bell indicator condition when receiving a matched 2-tone. The following conditions can be

 

programmed:

 

 

 

Null - The bell indicator condition is not changed, even when a matched code is received.

 

Off - The bell indicator goes off.

 

 

 

On - The bell indicator appears until a key is pressed.

 

 

 

Blink - The bell indicator blinks until a key is pressed.

 

 

 

 

 

 

ANS

Turns the Answer Back function on and off. This function transmits a 1 kHz single tone for 2 seconds when

 

receiving a matched 2-tone code.

 

 

 

 

 

 

EXO

“On” activates an external alert such as a horn or buzzer when a matching 2-tone code is received. The activa-

 

tion time is set by “EXO Timer” in the Rx Code Common screen (see below). The optional accessory cable is

 

required to utilize this feature.

 

 

 

 

 

 

 

 

 

 

 