Before you start !
Handle with spare fuse
(C) Tilthead with locking umbrella holder

Before you start !

English

The D-Lite it (Multivoltage) units are adapted for operation on 90 - 260V/50 - 60Hz. Before con- necting for the first time, check to make sure that your Modelling Lamp coincides with the voltage. They must always be connected to an earthed ( grounded) mains supply. All D-Lite it units have a bayonet mount and locking ring fitting, for fixing all Elinchrom and Prolinca accessories.

The Refllector Bayonet supports Refllectors and Softboxes up to 1.5 kg, e.g. Rotalux 100 x 100 cm . Mount the unit securely to a suitable stand or support.

Remove the black protective cover. DO NOT operate the unit without first removing the black protective cover.

Operating instructions

1.Check that the modelling lamp voltage is correct.

2.Check that the mains switch (2) is in the position OFF ("O" position).

3.Insert the mains cable into the MAINS INLET (1) and connect this to a FULLY EARTHED OUTLET 4.Using the mains SWITCH (2), switch the unit ON ("I" position).

5.Connect the synchro cord to its socket (5). 6.Select the power with the touch pad (10)

(A) Locking ring

(B)Protective cover (26124)

Switch and fuse

Mains supply

Use only the Elinchrom mains cord. Switch off the unit before the mains cord is connected to the mains plug.

Mains fuse

Standard type 5 x 20 mm, use only tempered fuse 8 AT (code 19022) for D-Lite it

Note: Before exchanging a blown fuse, switch off the unit and remove the mains cable. Open the little drawer in the mains plug with a screwdriver and replace the fuse with the spare fuse, which is placed in its support in this drawer. (N.B. Please don’t forget to check the correct value of the fuse!).

Fuse for modelling light

Fast type 5 x 20mm, 2.5 AF

Switch off the unit and replace the blown fuse with a new one of the correct value.

The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore the flash tube.