Programmable features - Reset | English |
How to „Reset“ the D-Lite it
In case you need to „RESET“ the
1.Switch the unit “off“
2.Press both flash power up / down buttons (10) at the same time and switch the unit on
3.The Digital LED multi display (6) flashes in fast mode
4.Do not continue to press the buttons, the resetting procedure is completed
Modelling lamp features & setup
Modelling lamps and fuses for 110 V & 230 V
Unit | Modelling lamp 110V | Modelling lamp 230V | Socket | Fuse |
100W / 23006 | 100W / 23002 | E27 | 2.5AF / 19035 | |
100W / 23006 | 100W / 23002 | E27 | 2.5AF / 19035 |
* Do not use energy saving lamps
Modelling lamp modes
>Setting: • Press “Modelling” button to set Modelling lamp ON to proportional mode, max. mode, min. mode, or OFF
•Press “Modelling” up or down button to set Modelling lamp to free mode, press “Free/Prop” to switch Modelling lamp OFF.
>LED Indication: • LED is on: only in proportional mode.
•LED is off: in min. / max. / off mode.
!• Please use only original ELINCHROM modelling lamps with a maximum power of 100W ( effective 150W).