Elmo ISP manual Current loop, Current limits, Time dependent peak current limit

Models: ISP

1 77
Download 77 pages 30.56 Kb
Page 11
Image 11

11

4.4Current loop

Current loop control is obtained by op amp U1/B (Current amplifier) and R7, C2 which form a lag-lead network for current loop. The standard amp is equipped with R7 (100Kohm) and C2 (0.01 æF) to get optimum current response for an average motor in this power range. These components are mounted in solderless terminals.

4.5Current limits

The servo amplifier can operate in the following voltage-current plane:

 

 

 

 

+V

 

 

 

-Ip

 

-Ic

 

 

Ic

 

Ip

Intermittent

 

Continuous

 

 

 

 

zone

 

zone

 

-V

 

 

 

 

Ic - Continuous current

Ip - Peak current

 

 

 

 

Fig. 4.1: Voltage-Current plane

 

Each amplifier is factory calibrated to have this shape of voltage-current operating area with rated values of continuous and peak current limits. In addition the peak current limit is time dependent as explained in 4.5.1.

4.5.1Time dependent peak current limit

The peak current is so designed that its duration is a function of the peak amplitude and the motor actual operating current before the peak demand. The maximum peak current is available for 1.6 second. The duration of Ip is given by:

ISP - Rev 6/95

Page 11
Image 11
Elmo ISP manual Current loop, Current limits, Time dependent peak current limit