Elmo ISP manual Tables and Summaries Adjusting trimmers, LED diagnostics

Models: ISP

1 77
Download 77 pages 30.56 Kb
Page 44
Image 44

44

9.Tables and Summaries

9.1Adjusting trimmers

Six trimmers are installed on the ISP board with the following functions:

T7 (Gain 1) - CW rotation increases input 1 gain.

T6 (Gain 2) - CW rotation increases input 2 gain.

T5 (Balance) - see 8.1.

T4 (compensation) - See 8.6.

T3 (Ip) - CW rotation increases peak current limit (see 8.2).

T2 (Ic) - CW rotation increases continuous current limit (see 8.2)

9.2LED diagnostics

Four LEDs are installed on the ISP with the following designations: Ic, In, Vs, SO. Under normal operation only Vs should illuminate (Vs indicates the existence of supply voltages). The following table represents the faults indications of the LEDs:

 

1

2

3

Ic

 

X

 

In

X

 

 

Vs

X

X

X

SO

 

 

X

X - Illuminated LED

1.One or more of: external inhibit, under/over voltage, short circuit, excess temperature, loss of tacho or insufficient load inductance.

2.Continuous current limit.

3.The shunt is "ON".

ISP - Rev 6/95

Page 44
Image 44
Elmo ISP manual Tables and Summaries Adjusting trimmers, LED diagnostics