Continuous current limit contouring:
| 1 | - | r1 |
R11 | = 18.3 | (Kohm) | |
| 1 | - | r2 |
|
| R11 | |
R10 | = 36.6 | (Kohm) | |
| R11 | + 20r1 |
Peak current limit contouring:
| 1 | - | s1 |
R13 | = 18.3 | (Kohm) | |
| 1 | - | s2 |
|
| R13 | |
R12 | = 36.6 | (Kohm) | |
| R13 | + 20s1 |
Dynamic contouring with armature voltage feedback
-IxR compensation must be activated as in 7.3
-Connect the Back EMF (terminal
-Remove R31.
-Insert R2 = 470 Ohm
-Insert R9 = 301 Kohm
-Calculate and insert R14 as in 7.1.4.
ISP - Rev 6/95