7.1.4Activating the loss of tacho protection (velocity mode only)

Activating the loss of tacho protection is done by installing R14 (different

value for 65V or 135V amplifiers),R15, and R16 as follows:

 

1530

 

R14

(65V) = -------

(Kohm)

 

Vam

 

 

2730

 

R14

(135V) = ------

(Kohm)

 

Vam

 

 

100 x Vam

 

R15

= -----------

(Kohm)

 

Ip x Rm

 

R16

< 10 ohm

 

Vam - Armature voltage at maximum application speed.

Ip - Amplifiers' rated peak current limit.

Rm - Total ohmic resistance of motor.

R9 should be calculated and inserted according to the tacho voltage at maximum application velocity (Vtm):

For Vtm > 7.5V:

insert R9 = 301Kohm.

For Vtm < 7.5V:

2250

R9 = -------

(Kohm)

Vtm