Elmo manual Terminals for ISP mounted in 3U size ENC, Gnd

Models: ISP

1 77
Download 77 pages 30.56 Kb
Page 22
Image 22

22

5.3Terminals for ISP mounted in 3U size ENC.

The MBA-ISP/3UE is designed for Elmo enclosures. It has screw type terminals for the power and D-type connectors for the signals.

The Potential Free Inhibit Input is applicable only when the "inverted inhibit logic" is used (R18 in the amplifier is inserted). An opto-Coupler (IL5) is used to isolate between the Inhibit signal and the amplifier circuit. Activating this opto-coupler is done by inserting R1 on the mother board according to the following relation:

R1 = 100 x Vinh (ohm)

Vinh - voltage in the inhibit input.

Standard value is 2.4K (For 24 volts) Source must be capable of source or sink 10mA.

Power Terminals

Terminal

Function

Remark

 

 

 

AC

AC input

 

M1

Armature

This output will be negative when a positive signal

 

output

is fed to one of the inputs.

M2

Armature

This output will be positive when a positive signal

 

output

is fed to one of the inputs.

AC

AC input

 

GND

Ground

 

 

 

 

ISP - Rev 6/95

Page 22
Image 22
Elmo manual Terminals for ISP mounted in 3U size ENC, Gnd