Manuals
/
Emerson
/
Personal Care
/
Oxygen Equipment
Emerson
51-DO-03, 51-DO-04
instruction manual
Section
Models:
51-DO-04
51-DO-03
DO-04
DO-03
1
20
70
70
Download
70 pages
4.9 Kb
17
18
19
20
21
22
23
24
<
>
Troubleshooting
Specifications
Install
Alarm Status
Alarm Fault
Interval timer
Section Wiring
Warranty
Dimension
Maintenance
Page 20
Image 20
MODEL
DO-03/04
SECTION 3.0
WIRING
FIGURE
3-2.
Model
DO-03
— Wiring Air Blast Compressor to Model 54eA Analyzer 115 Vac
14
Page 19
Page 21
Page 20
Image 20
Page 19
Page 21
Contents
Dissolved Oxygen Measurement System with Air Blast Cleaner
Model DO-03/04
Essential Instructions
Page
Model DO-03/04 Measuring System
Section Title
11.0
List of Tables
10.0
Iii
List of Figures
Section Title
Section Specifications
Features and Benefits
Power
Repeatability ±0.05 ppm 25C
RFI/EMI EN-61326
Output Accuracy ± 0.05 mA
Materials of Construction
Maximum continuous pressure 50 psig 446 kPa abs
Maximum distance between compressor and sensor
Analyzer dimensions
Enclosure dimensions
9240048-00 Tag, stainless steel, specify marking
Power required selection
Description
Section Installation
Installation
Unpacking and Inspection
Model or part number Description
Assembling the pipe and pipe clamp
Installing the air compressor enclosure
Installing the handrail mounting assembly
Assembling the washer head and pipe boom
Installing the sensor in the washer head assembly
Attaching the pipe boom to the handrail mounting assembly
Attaching the air compressor enclosure to the handrail
Installing the sensor in the washer head assembly
General
Section Wiring
POWER, ALARM, and Output Wiring
454EPH02
Section
Section
General
Sensor Wiring
Wiring the Oxygen Sensor
Alarm Status
Section Display and Operation
Display
KEY Functions and Control
Section Software Configuration
Menu Tree for the 54eA Analyzer
On following
Main Menu Calibrate See Diagnostic Variable see
Program Settings List
Choices Factory Settings Setpoints
Choices Factory Settings Configure
Choices Factory Settings
Alarm setpoints
Alarm 1 setpoint
Alarm 2 setpoint
Alarm 3 setpoint
MA 0.00 ppm 20 mA 20.00 ppm Output 1 12.00 mA
Ranging the Outputs
Test output
Test alarm 1 Open
Simulated tests
Outputs Alarms
Display
Measure Oxygen
Meas units ppm
Language English Display left Display right Out
Display contrast Timeout On
Temp units C Output 1 mA Output 2 mA
Output Measurement
Outputs
Output 1 control
Range 4-20 mA Dampen 0 sec Hold Last Value
Output 1 Setup
Output 1 Control
Configure
Alarm 1 control
Alarm 1 setup Alarm 2 control
Changing Alarm Parameters
Alarm 1 control
Alarm 1 setup
Alarm Low
Activate Process
Alarm Fault
Feed limit Disable
Timeout 3600 sec
Alarm 4 setup
Alarm 4 setup Feed limit timer
Interval timer
Timer Disable Timer Time activated Interval 24.0 hr
Interval timer setup
Temperature Compensation and Temperature Units
Temp comp Auto
Temp units C
Temp comp Manual Temp units C
60 Hz
Noise Reduction
Barometric Pressure
Bar meas Auto
Bar units mm Hg
Main sensor cal
Salinity 0.0 o/oo
Noise rejection Main sensor cal Security
Security
Action Definitions
Analyzer Mode Priority
Condition Definitions
Section Calibration Temperature
Introduction
Adjust temp + 025.1 C
Temperature Calibration
Section Calibration Dissolved Oxygen
Sensor Current as a Function Dissolved Oxygen Concentration
Sensor must be in zero solution
Zeroing the Sensor
Stabilizing . . . Wait
Calibrating the Sensor in AIR
Section
Calibrate 8.32 ppm
Calibrating the Sensor Against a Standard Instrument
Zero main sensor Adjust temperature
Calibrate main sensor
Standardize
Calibrating Barometric Pressure
Section Calibration Current Outputs
Trimming the Outputs
Section Maintenance
Replacement Parts
Cleaning the membrane
Replacing electrolyte solution and membrane
Section
Power Fuse
Spare Parts
Replacement Parts Location Part Number Description
AIR Blast Sensor Washer
Section Troubleshooting
Troubleshooting When a Fault Message is Showing
Fault message Explanation See Section
Overview
Temperature error low or high
High input current
Check sensor zero
Sense line open
Zero current is too high
Troubleshooting When no Fault Message is Showing Oxygen
Problem See Section
Barometric pressure reading is too high or too low
Possible error warning during in-process calibration
Zero reading Is unstable
Process readings are erratic
Readings drift
Sensor does not respond to changes in oxygen level
Oxygen readings are too low
Troubleshooting not Related to Measurement Problems
Problem Action
Simulating Inputs Dissolved Oxygen
Sensor Polarizing Voltage Resistance Expected current
Simulating Temperature
Simulating temperature
Section Return of Material
General
Return of Materials Request
Sensor or Circuit Board only
Warranty
Specifications subject to change without notice
Top
Page
Image
Contents