Emerson 8800 instruction manual Remove Solenoid Valves, Remove EMI Filter and Terminal Block

Models: 8800

1 154
Download 154 pages 45.63 Kb
Page 85
Image 85

Instruction Manual

IM-106-880, Rev 1.0 January 2007

OCX 8800

Remove Solenoid Valves

1.Disconnect solenoid leads from mating terminal connector.

2.Remove top nut of solenoid valve (15 or 16, Figure 6-20).

3.Remove the solenoid coil assembly and washer.

4.Unthread and remove solenoid valve base.

Remove EMI Filter and Terminal Block

Figure 6-21. Removal/ Installation of EMI Filter

Electronics Housing Assembly

1.Disconnect EMI filter wiring (Figure 6-21)at terminal block (3).

2.Disconnect EMI filter wiring at AC power input terminal block on electronic stack.

3.Unbolt and remove EMI filter (1) from electronic stack.

4.Remove ground wire (2) from terminal block (3).

5.Unbolt and remove terminal block (3) from electronic stack.

Brown

Blue

Blue

Brown

 

Green

 

Green

Green

1

 

2

3

37390083

 

Install EMI Filter and Terminal Block

1.Install replacement EMI filter (1, Figure 6-21)and/or terminal block (3) on electronic stack.

2.Refer to wiring details in Figure 6-21.Connect EMI filter wiring and ground wire (2) at terminal block (3).

3.Connect EMI filter wiring at AC power input terminal block on electronic stack.

6-27

Page 85
Image 85
Emerson 8800 Remove Solenoid Valves, Remove EMI Filter and Terminal Block, Install EMI Filter and Terminal Block