Emerson 8800 instruction manual Installation, OCX

Models: 8800

1 154
Download 154 pages 45.63 Kb
Page 24
Image 24

OCX 8800

Figure 2-1. Installation, OCX 8800

NOTE

All dimensions are in inches with millimeters in parentheses.

Insulate if exposed to adverse weather or extreme temperature changes, install a protective housing and/or insulation around the unit.

Dim “B”

Removal Envelope

Allow 9 in.

Flange Dia.

 

(229 mm) for

 

Cover Removal

B.C. Dia.

Hole Dia.

Table 1. Mounting Flange

ANSI DIN 5R10244H01 5R10244H02

Flange

6.00

7.28

Dia.

(152)

(185)

Hole

0.75

0.71

Dia.

(19)

(18)

(4) Holes

4.75

5.71

equally

spaced on

(121)

(145)

B.C. dia

BOTTOM VIEW

Instruction Manual

IM-106-880, Rev 1.0

January 2007

0.06In. Thick Gasket ANSI 3535B18H02

DIN

3535B45H01

Dim “A”

Insertion Depth

Table 2. Installation/Removal

Probe

Dim “A”

Dim “B”

 

 

 

18 in.

18

34

(457)

(864)

 

3 ft

36

52

(914)

(1321)

 

6 ft

72

88

(1829)

(2235)

 

9 ft

108

124

(2743)

(3150)

 

Optional

In Situ Filter

8.3

 

(211)

37390008

 